repower 6v series power battery test system can test various power batteries (lithium batteries , lead-acid batteries , nickel-cadmium battery , nimh batteries) for
electrical performance testing , which can meet the real road condition simulation test requirements of the battery to the greatest extent , and accurately sample
various battery parameters in real time, store, analyze, and give early warning to provide reliable data reference for battery research, development and production.
test functionality
cycle life test
capacity test
charge and discharge test
temperature
characteristics test
charge retention capability
dynamic and static
soc test
high-speed pulse test
dcir test
advantages and features
upgraded module 96ch in 1 cabinet
using single channel & board design, performance and stability are greatly improved. high integration, less wires, easy to use and maintain.
multi-range higher accuracy
the current levels are 25%f.s, 50%f.s, 100%f.s;
grading current accuracy: 0.02%fs.
ultra-wide voltagerange support -6v to 6v
wide testing range;when testing negative voltage batteries, it can deliver a continuous voltage output of up to 6v without exceeding the maximum power of the equipment.
24 hours offline
after the host computer communication is interrupted, the equipment can run offline with full functions for 24 hours and automatically connect after communication is restored. testing without interruption to ensure data integrity and security.
high-speed road condition simulation
maximize to meet the battery real road condition simulation test;
satisfy all high-speed dynamic tests in the laboratory;
minimum time interval 10ms, support current/power conditions excel import.
intelligent software
comparison of multi-channel charge and discharge curves , multi-channel battery data synchronization, supporting battery fitting consistency analysis to quickly identify abnormal batteries.
product parameters
voltage
scope
0v~±6v
accuracy
± 0.02% f.s
resolution
0.1mv
current
scope
100a/200a/300a/500a…2000a
accuracy
± 0.02% f.s. is divided into three levels: 25%, 50%, 100%
resolution
0.1ma
current response time
5ms(10%~90% f.s)
current switching time
10ms(-90%~90% f.s)
minimum operating interval
10ms
communication
lan
third-party/auxiliary module linkage
support linkage with temperature box, mtv/mts, pressure sensor, etc.
equipment size (w*d*h mm)
600*850*1030 / 600*800*1980
note: for specific models and parameters, please refer to the corresponding technical specifications.