rcds-多宝体育官方网站app下载

module/pack test system hrcds-100v60a-c/hrcds-100v30a-c
product detail

module/pack test system

hrcds-100v60a-c

hrcds-100v30a-c



application fields


this system is designed for testing lithium or lead-acid battery packs used in electric bicycles, power tools, e-motorcycles, drones, medical devices, robotic vacuums, balance scooters, and vacuum cleaners. it is suitable for production lines and quality control, enabling integrated monitoring of charge/discharge data.




testing functions


cycle life test

capacity test

charge/discharge test

charge retention test

overcharge/

overdischarge test

temperature characteristics test

working condition

pulse test

dcir test


advantageous features



energy feedback


the system supports high-quality discharge energy is fed back to the grid with an efficiency of 91%.  the two-way energy saving of charging and discharging reduces both electricity costs and heat-related air conditioning expenses.

multi-protection


built-in protections include power failure protection, open circuit, short circuit, reverse polarity, overcurrent/overvoltage.

high and low temperature double protection, full temperature range monitoring.



high precision & fast response


stable and accurate current and voltage sampling, using high-resolution adc units with excellent long-term stability.

offline operation


supports offline testing to ensure data safety and integrity. data channel migration is also supported.

communication function


each channel is equipped with can and rs485 communication modules, enabling bms can communication function: real-time bms data acquisition, big data analysis, and report generation.

support third-party equipment control

controlling the temperature chamber and other equipment in the testing process, the relevant tests  are saved together to meet the battery testing requirements (optional, the third party provides relevant agreements).



product parameters

model no.:

hrcds-100v60a-c

hrcds-100v30a-c


single channel

voltage

single channel

measurement range

0v~100v

minimum output

current

5v (device port output)

3v (device port output)

accuracy

± 0.05% f.s

resolution

0.1mv


single channel

current

single channel

measurement range

±60a

±30a

minimum output

current

50ma

accuracy

± 0.05% f.s

resolution

0.1ma

current response time

4ms(10%~90% f.s)

current switching time

5ms(-90%~90% f.s)

device and control computer communication method

lan

battery bms communication

support can;rs485 communication;uart ttl communication(with adapter box)

support dbc import, can realize data reading with bms can, and participate

in process control.

third party / auxiliary module linkage

support linkage with temperature chamber, mtv/mts, pressure sensor, etc.

equipment size (mm)

600*800*1980


note: for specific models and parameters, please refer to the corresponding technical specifications.

homeaboutproducts & solutionscasesservicenews centercontact us
repower technology co., ltd
addresstower 3a & 3b,shangzhi park, guangming district, shenzhen,china
customer
hotline
4000-188-189
网站地图